Inter-atrial septum stenting in congenital heart disease patient: a case series in Indonesia

Penulis: Radityo Prakoso, Yovi Kurniawati, Sisca Natalia Siagian, Aditya Agita Sembiring, Damba Dwisepto Aulia Sakti
Informasi
JurnalCardiovascular & Hematological Disorders-Drug Targets
PenerbitBentham Science Publishers
Volume & EdisiVol. 24,Edisi 3
Halaman163-171
Tahun Publikasi2024
Jenis SumberGoogle Scholar
Sitasi
Google Scholar: 1
Abstrak
BackgroundInter-atrial septum (IAS) stenting in duct-dependent congenital heart disease patient has shown to be an effective way to maintain inter-atrial blood flow, however it is still considered a high risk procedure and inter-atrial septum stenting remains a low-frequency procedure.MethodsA single-center observational cohort study was carried out at the National Cardiovascular Center Harapan Kita (NCCHK) between April 2019 and April 2023. This study included duct-dependent congenital heart disease patients. The extracted data were baseline characteristics, clinical findings, complications, and outcomes of the patients.ResultsEleven patients with duct-dependent physiology were intervened with inter-atrial septum stenting. The patients were 4 females and 7 males with the median age of implantation being 150 days (range 11-703 days) and the median weight being 3.9 (range 2.8-9) kg, with 2 patients …