Diluted Indocyanine Green Angiography: A Novel Approach to Free Flap Perfusion Evaluation in Reconstructive Microsurgery

Penulis: Atmodiwirjo, Parintosa; Ramadan, Mohamad Rachadian; Wicaksana, Aditya; Djohan, Michael; Amanda, Nadira Fildza
Informasi
JurnalPlastic and Reconstructive Surgery - Global Open, Plastic and Reconstructive Surgery Global Open
PenerbitLippincott Williams and Wilkins, Wolters Kluwer Health
Volume & EdisiVol. 12,Edisi 11
Halamane6280 -
Tahun Publikasi2024
ISSN21697574
eISSN2169-7574
Jenis SumberScopus
Sitasi
Scopus: 2
Google Scholar: 2
PubMed: 2
Abstrak
Background: Assessing perfusion in free flaps is crucial in clinical practice. Indocyanine green (ICG) angiography offers a more objective and reproducible method, utilizing near-infrared imaging to monitor flap vascularization. This study aims to evaluate the efficacy of diluted ICG as a tool for assessing free flap perfusion. Methods: This pilot randomized clinical trial compares the fluorescence concentrations of ICG at 3 different dilutions: 5 mg/mL (standard concentration), 2.5 mg/mL (half the standard concentration), and 0.5 mg/mL (one-tenth of the standard concentration). Inclusion criteria required participants to have serum albumin levels above 3 g/dL, hemoglobin levels over 10 g/dL, and no comorbidities. Participants were randomized into 3 groups based on ICG concentration. Fluorescence analysis was performed using ImageJ software to determine mean gray values. Both surgeons and data analysts were blinded to the ICG concentrations administered, ensuring unbiased evaluation. Results: Forty-five patients undergoing free flap surgery, predominantly male (60%) with a mean age of 37.76 ± 19.79 years and a mean body mass index of 21.23 ± 4.49kg/ m2 primarily received osteoseptocutaneous fibular free flaps (46.67%), with an average skin flap area of 66.07 ± 46.94 cm2. The primary etiology was underlying tumors (84.4%), with the head and neck as the most common reconstruction site (82.2%). The superior thyroid artery was the most frequently used recipient vessel (37.78%). Analysis revealed mean gray values of 64.10 ± 8.27 (5mg/mL), 79.03 ± 2.7 (2.5mg/mL), and 33.56 ± 3.47 (0.5mg/mL), with 2.5mg/mL yielding the highest value (P < 0.001). Conclusions: Findings suggest using 2.5 mg/mL concentration enhances fluorescence emission, offering a dosage alternative in clinical practice. Copyright © 2024 The Authors.
Dokumen & Tautan

© 2025 Universitas Indonesia. Seluruh hak cipta dilindungi.