A rare case of oxidized zirconium - All polyethylene tibia unicompartmental arthroplasty failure: A case report

Penulis: Pontoh, Ludwig Andre; Dilogo, Ismail Hadisoebroto; Kamal, Achmad Fauzi; Widodo, Wahyu; Fiolin, Jessica
Informasi
JurnalInternational Journal of Surgery Case Reports
PenerbitElsevier Ltd
Volume & EdisiVol. 94
Halaman -
Tahun Publikasi2022
ISSN22102612
eISSN2210-2612
Jenis SumberScopus
Sitasi
Scopus: 2
Google Scholar: 2
PubMed: 2
Abstrak
Oxidized zirconium (Oxinium) implants has been claimed as the best material in terms of wear reduction. However, longevity of an all polyethylene uni knee arthroplasty (UKA) has been a long debate. We reported a rare case of 74 year old female who was performed all polyethylene UKA 6 years prior and fell 3 months prior. After the incident, patient was wheel-chair ridden afterwards. There was no evidence of fracture upon conventional radiography examination. Conversion of UKA to total knee replacement (TKA) was performed and patient was able to walk with aid after the surgery. The failed Oxinium all polyethylene UKA failure in this case is suspected due osteoarthritis progression. © 2022 The Authors
Dokumen & Tautan